R32 Full DC quiet inverter swimming pool heat pump

Home/Product/Swimming Pool Heat Pump/R32 Inverter Heat Pump/R32 Full DC quiet inverter swimming pool heat pump

R32 Full DC quiet inverter swimming pool heat pump

POOLWORLD R32 Full DC quiet inverter swimming pool heat pump with ABS anti-corrosion and multi-color casing, which can better suit the outdoor installation location and fit the different decoration styles.

Brand:POOLWORLD

Item:R32 Quiet Pro Series

Application:Four Seasons Pool Heating

Description

Product Features:

POOLWORLD provides a heating and cooling solution for the swimming pool — POOLWORLD R32 Full DC quiet inverter swimming pool heat pump. Its low noise and high COP makes it the ideal pool heat pump for different kinds of the pool, such as an above-ground pool.

  1. ABS anti-corrosion casing
  2. Embedded LCD control panel
  3. COP as high as 15.0
  4. Noise as low as 38dB
  5. Multiple Casing Colors

Product Advantages:

  • ABS Anti-Corrosion Casing 
    ABS material has high strength, toughness, and low-temperature resistance. Compared with metal shells, it is more anti-corrosion and more suitable for coastal areas. With the ABS anti-corrosion casing, POOLWORLD R32 Full DC quiet inverter swimming pool heat pump can be installed outdoors and has a long service life.
  • Screwless Design
    The appearance of the screwless design ensures the overall craftsmanship of the quiet heat pumps. The screws are designed to be hidden or snapped to ensure that the overall appearance of the unit is free of screws.
  • Multiple Casing Colors
    The highly malleable ABS material allows this model to have more color options. Black, white, green, titanium gold, rose gold, silver, etc. The diverse casing colors of the quiet pool heat pump can better suit different decoration styles. More colors are waiting for you to add.

pool heat pump for above ground pool

● Embedded LCD Control Panel

The new 5-buttons embedded LCD control panel is cleverly integrated with the exterior design. In this way, users can better operate the pool heat pump directly.

pool heat pump for above ground pool

 

● COP as high as 15.0
    1、COP is up to 15.0 at Air 27°C / Water 26°C / Humidity 80 %
    2、Operating at air -7°C – Maximize your pool season.
    3、The average COP is 11.0 during the swimming season.

 

● Noise as low as 38dB

  1. The compressor’s space is wrapped with silencing materials. A fully enclosed design is adopted to implement three noise reduction measures of sound absorption, sound insulation, and buffering for the entire unit to ensure low-noise operation.
  2. The quiet heat pump with multiple noise reduction technology designs, suitable wind field flow channel design, and noise reduction treatment for compressors, cabinets, etc., through elimination, isolation, and suction, provides a low noise experience for users.
  3. Shock-absorbing design. There are damping blocks on the copper pipes to reduce vibration and improve the unit’s reliability. Reduce the unit’s vibration, reduce the noise, and improve the unit’s life.

pool heat pump for above ground pool

  • Wifi Function
    POOLWORLD not only provides a high-efficiency and quiet heat pump but also figures out a smart heating and cooling solution to control the pool heat pump with an APP.

pool heat pump for above ground pool

  • R32 Refrigerant
    R-32, also known as HFC-32, is an organic hydrofluorocarbon compound with the formula CH₂F₂. It’s a colorless, odorless, mildly flammable gas insoluble in water. R32 shall be the ideal refrigerant in the heating and cooling solution for its high efficiency and low environmental impact.
  • Save Energy and Heating Time
    With a leading and mature full DC inverter technology by POOL WORLD, this series can reach a high COP of 15.0, indicating in a short time heating, customers don’t need to wait for a long time to enjoy swimming. In the meanwhile, it can save up to 50% energy consumption compared to ON/OFF units.

pool heat pump for above ground pool

  • Intelligent Defrosting
    The R32 Full DC quiet inverter swimming pool heat pump is the heating and cooling solution with a four-way valve intelligent reversing defrost multi-point control. Fast defrosting speed, multi-point comprehensive control of time and temperature, reduces defrosting time, and improves unit operating efficiency.

pool heat pump for above ground pool

Specifications:

ModelPW010-KZXYC-HPW015-KZXYC-HPW020-KZXYC-HPW030-KZXYC-HPW040-KZXYC-HPW050-KZXYC-HPW060-KZXYC-H
Advised pool volume (m3)15~3020~4025~5030~6040~7555~10055~100
Operating air temp. (℃)-7 ~43
Performance Condition: Air 27°C, Water 26°C, Humidity 80%
Heating capacity (kW)7.50~1.929.50~2.1011.00~2.5014.00~3.1517.00~3.7520.00~4.0024.00~4.80
Heating Capacity(Btu)25500~652832300~714037400~850047600~1071057800~1309068000~1360081600~16320
Consumed power (kW)1.15~0.131.46~0.141.83~0.172.15~0.212.62~0.253.33~0.274.00~0.32
COP6.5~14.86.5~15.06.0~14.76.5~15.06.5~15.06.0~14.86.0~15.0
COP at 50% capacity10.5111110.5111111
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)5.80~1.427.20~1.508.50~1.6510.70~2.4013.00~2.6515.6~2.8518.70~3.42
Heating Capacity(Btu)19720~482824480~510028900~561036380~816044200~901053040~969063580~11630
Consumed power (kW)1.15~0.201.43~0.211.77~0.232.12~0.342.58~0.363.25~0.403.89~0.49
COP5.0~7.15.0~7.24.3~7.25.0~7.15.0~7.44.8~7.04.8~7.0
COP at 50% capacity6.56.56.56.56.56.56.5
Performance Condition: Air 35℃,Water 28℃, Humidity 80%
Cooling capacity (kW)4.0 5.267.28.610.111.8
Sound pressure at 1m dB(A)38~4838~4840~5042~5143~5243~5344~54
Sound pressure of 50% capacity at 1m dB(A)40404143444445
Sound pressure at 10m dB(A)18~2518~2519~2622~2723~3024~3125~32
Heat exchangerSpiral titanium tube in PVC
CasingABS Plastic Casing
Power supply220~240V/1 Ph/50~60Hz
Water connection (mm)Φ50
Rated input current at air 15℃(A)5.1~0.96.3~0.97.8~1.09.3~1.511.3~1.614.3~1.817.8~2.3
Water flow volume(m³/h)2~42~43~54~66~98~109~12
Water pressure drop (max) kPa2345568
Net weight/Gross weight(kg)62/7062/7064/7277/8781/9181/9190/100
Net size(mm)1000*396*6401125*416*765
Package size(Carton)(mm)1040*410*7801165*430*905
Package size(Polywood)(mm)1060*430*7801185*450*905
Loading qty(20GP/40GP/40HQ)78/162/16252/104/104
RefrigerantR32
Compressor type/QTYRotary type/1
DefrostingBy four way valve
Throttle deviceElectronic expansion valve
Operating water temp. (℃) *heating9 ~43
Operating water temp. (℃) *cooling9 ~35
Note:The data above is for reference only,please refer to the nameplate on the unit if for more specific data.
ModelPW010-KZXYC-HPW015-KZXYC-HPW020-KZXYC-HPW030-KZXYC-HPW040-KZXYC-HPW050-KZXYC-HPW060-KZXYC-H
Advised pool volume (m3)15~3020~4025~5030~6040~7555~10055~100
Operating air temp. (℃)-7 ~43
Performance Condition: Air 27°C, Water 26°C, Humidity 80%
Heating capacity (kW)7.50~1.929.50~2.1011.00~2.5014.00~3.1517.00~3.7520.00~4.0024.00~4.80
Heating Capacity(Btu)25500~652832300~714037400~850047600~1071057800~1309068000~1360081600~16320
Consumed power (kW)1.15~0.131.46~0.141.83~0.172.15~0.212.62~0.253.33~0.274.00~0.32
COP6.5~14.86.5~15.06.0~14.76.5~15.06.5~15.06.0~14.86.0~15.0
COP at 50% capacity10.5111110.5111111
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)5.80~1.427.20~1.508.50~1.6510.70~2.4013.00~2.6515.6~2.8518.70~3.42
Heating Capacity(Btu)19720~482824480~510028900~561036380~816044200~901053040~969063580~11630
Consumed power (kW)1.15~0.201.43~0.211.77~0.232.12~0.342.58~0.363.25~0.403.89~0.49
COP5.0~7.15.0~7.24.3~7.25.0~7.15.0~7.44.8~7.04.8~7.0
COP at 50% capacity6.56.56.56.56.56.56.5
Performance Condition: Air 35℃,Water 28℃, Humidity 80%
Cooling capacity (kW)4.0 5.267.28.610.111.8
Sound pressure at 1m dB(A)38~4838~4840~5042~5143~5243~5344~54
Sound pressure of 50% capacity at 1m dB(A)40404143444445
Sound pressure at 10m dB(A)18~2518~2519~2622~2723~3024~3125~32
Heat exchangerSpiral titanium tube in PVC
CasingABS Plastic Casing
Power supply220~240V/1 Ph/50~60Hz
Water connection (mm)Φ50
Rated input current at air 15℃(A)5.1~0.96.3~0.97.8~1.09.3~1.511.3~1.614.3~1.817.8~2.3
Water flow volume(m³/h)2~42~43~54~66~98~109~12
Water pressure drop (max) kPa2345568
Net weight/Gross weight(kg)62/7062/7064/7277/8781/9181/9190/100
Net size(mm)1000*396*6401125*416*765
Package size(Carton)(mm)1040*410*7801165*430*905
Package size(Polywood)(mm)1060*430*7801185*450*905
Loading qty(20GP/40GP/40HQ)78/162/16252/104/104
RefrigerantR32
Compressor type/QTYRotary type/1
DefrostingBy four way valve
Throttle deviceElectronic expansion valve
Operating water temp. (℃) *heating9 ~43
Operating water temp. (℃) *cooling9 ~35
Note:The data above is for reference only,please refer to the nameplate on the unit if for more specific data.

    Contact Us