R32 Monoblock house heating and cooling heat pump

Home/Product/Heating & Cooling & DHW Heat Pump/R32 Monoblock house heating and cooling heat pump

R32 Monoblock house heating and cooling heat pump

R32 Monobloc Heat Pump applies EVI technology and features A+++ efficiency with 5 operation modes, smart operation, and screwless monobloc design, which have a great performance in house heating and cooling.

Brand:POOLWORLD.

Item:R32 Monoblock Type.

Function:Supply house heating/cooling and hot water.

Description

Product Features:

R32 Monoblock house heating and cooling heat pump provides house heating, cooling, and hot water, whose five features make the R32 Monobloc heat pump from POOLWORLD out of other domestic air source heat pumps.

  1. ErP A+++ energy label
  2. EVI technology
  3. R32 refrigerant
  4. 5 opertion modes
  5. Wifi function

Product Advantages:

POOLWORLD, a professional domestic air source heat pump manufacturer, has devoted itself to the R32 heat pump for many years to give users a better and more comfortable experience.

  • Screwless Design

    The appearance of the screwless design ensures the overall craftsmanship of the product. The screws are designed to be hidden or snapped to ensure that the overall appearance of the R32 monobloc heat pump is free of screws.

R32 Split EVI DC Inverter Heat Pump

  • 5 Operation Modes

    The R32 Monobloc heat pump has 5 optional operations, which help offer the users comfortable house heating/cooling and stable hot water supply (by a 3-way valve) all year round based on their demands.

    A. Single space heating;
    B. Single domestic hot water;
    C. Single space cooling;
    D. Space heating+DHW (hot water priority);
    E. Space cooling+DHW (hot water priority).

  • ERP A+++ Energy Label

    POOLWORLD applies DC inverter technology, which enables the R32 Monobloc heat pump to adjust its frequency from 30Hz to 90Hz according to actual heating requirements. With this technology, the POOLWORLD R32 heat pumps with EVI DC inverter (capacity range from 1.28kw to 30.7kw) reach the energy level of A+++ according to the ErP directive.

domestic air source heat pump

  • Color LCD Control Panel

    The R32 Monobloc heat pump has a control panel with a built-in WiFi module. APP can control the heat pump, including the temperature. The domestic air source heat pump with high-end touch capacitive screen, beautiful UI, and human-computer interaction design is easy to operate.

 

domestic air source heat pump

 

  • EVI Technology

    POOLWORLD R32 Monobloc heat pump uses special high-efficiency and high compression ratio Panasonic compressors, an internationally famous brand with low vibration and low noise, combined with ultra-low temperature jet enthalpy increasing technology, not only can it normally run at an ambient temperature of -30°C, but the maximum outlet water temperature of the unit is up to 60°C. To achieve high water temperature and hot water output. It makes the R32 domestic air source heat pump can even provide heating protection in severe cold areas.

  • Wide Range of Operation
    1. Using advanced controllers, single-camera units can operate normally at 170V-254V, and three-phase units can operate normally at 320-460V;
    2. Using DC frequency conversion technology, the unit can effectively heat between -30-43°C.
    • More Energy Efficient, More Comfortable

      With a leading and mature full DC inverter technology by POOLWORLD, the R32 Monobloc domestic heat pump’s heating time is shorter, more stable, and more comfortable. It can intelligently adjust the operating frequency of the compressor according to the ambient temperature, avoid frequent startup of the system, improve the working efficiency of the compressor, save 50% more energy power than an ON/OFF air source heat pump, and save 75% energy compared to the traditional heating system.

    • Multiple Noise Reduction Design

      The R32 domestic air source heat pump, with multiple noise reduction technology designs, appropriate wind field flow channel design, and noise reduction treatment for compressors, boxes, etc., through elimination, isolation, and suction, can provide a better user experience.

    • Full DC Brushless Inverter Motor

      The R32 Monobloc heat pump with full DC brushless inverter motor, stepless speed regulation can be performed according to system operation changes, to ensure the optimal state of system pressure, higher operating efficiency, more stability, large air volume and lower noise.

    • High-Efficiency Tank Heat Exchanger

      Using a high-efficiency tank heat exchanger, fluorine and water reverse heat exchange. The water circuit adopts a two-way countercurrent arrangement to enhance the fluidity of the water circuit and the subcooling (heat) of the refrigerant to achieve high-efficiency heat exchange; The high-efficiency tank adopts the integrated design of the water circuit, with no gaps, which reduces the leakage of the refrigerant, and has a more stringent pressure fatigue test, with a pressure bearing capacity of 20MPa.

 

Specifications:

ModelPD30-CRL-DCPD40-CRL-DCPD50-CRL-DCPD60-CRL-DCPD80-CRL-DCPD100-CRL-DC
HeatingHeating Capacity  Range (kW)1.57~8.404.40~13.005.9~18.27.5~23.010.2~28.012.8~35.0
Heating input  Range (kW)0.32~1.870.90~3.021.20~4.111.53~5.232.07~6.362.61~7.99
current  Range  (A) 1.42~8.301.39~4.68/
4.12~13.8
1.86~6.37/
5.49~18.8
2.37~8.113.70~11.44.67~14.3
COP Range4.49~4.914.30~4.904.43~4.924.40~4.904.40~4.924.38~4.90
CoolingCooling capacity  Range (kW)0.99~6.222.80~8.203.81~11.534.73~14.66.54~19.88.13~24.6
Cooling Input power(kW)0.29~2.180.85~3.311.11~4.051.39~5.141.92~6.972.42~8.75
current  Range  (A) 1.28~9.671.32~5.13/
3.89~15.1
1.72~6.28/
5.08~18.5
2.16~7.973.43~12.54.33~15.6
EER Range2.85~3.412.48~3.292.85~3.432.84~3.402.84~3.402.81~3.36
DHWHeating capacity  Range (kW)1.28~6.813.52~10.504.80~14.726.1~18.512.3~20.413.6~22.6
Heating input  Range (kW)0.31~2.130.88~3.391.17~4.601.53~5.972.8~5.373.09~5.95
current  Range  (A) 1.38~9.451.36~5.26/
4.03~15.5
1.82~7.15/
5.35~21.1
2.37~9.265.0~9.65.52~10.6
COP Range3.2~4.13.1~4.03.2~4.13.1~4.03.8~4.43.8~4.4
Power Supply230V/1Ph/50-60Hz380V-400V/3Ph/50-60Hz /
220V-230V/1Ph/50-60Hz
380V/3Ph/50-60Hz
RefrigerantR32
 Working  Area -30~43℃
Water Circulation (m³/H)1.4 2.2 3.1 4.0 4.86.0 
Water Pressure Drop (kPa)312535454050
IP Grade (Level of protection)IPX4IPX4IPX4IPX4IPX4IPX4
Anti-electric Shock RateIIIIII
Noise (dB(A))≤53≤55≤57≤58≤62≤66
Net Weight/Gross Weight(kg)110/120140/150170/180180/190210/220230/240
Diameter of Pipe (mm)DN25DN25DN25DN25DN32DN32
Body Size(W*D*H) (mm)970×475×8351100×475×9851050×480×13301050×480×13301160×500×15801160×500×1580
Loading Quantity (20GP/40GP/40HQ)44/88/8844/88/8822/46/4622/46/4618/40/4018/40/40
ErP Level (35°C)A+++A+++A+++A+++A+++A+++
ErP Level (55°C)A++A++A++A++A++A++
Condensor TypePlate Heat Exchanger
Fan MotorDC Type
Defrosting By Four-way valve
Operating Water Temperature (℃) DHW9~60℃
Operating Water Temperature (℃) Heating9~50℃
Operating Water Temperature (℃) Cooling7~35℃
Remark:
Heating working condition: Inlet water temperature 30℃, Outlet water temperature 35℃, Dry bulb temperature 7℃, Wet bulb temperature6℃.
Cooling working condition:Inlet water temperature 12℃, Outlet water temperature 7℃, Dry bulb temperature 35℃, Wet bulb temperature 24℃.
DHW working condition: Inlet water temperature 15℃, Outlet water temperature 55℃, Dry bulb temperature 7℃, Wet bulb temperature 6℃.
ModelPD30-CRL-DCPD40-CRL-DCPD50-CRL-DCPD60-CRL-DCPD80-CRL-DCPD100-CRL-DC
HeatingHeating Capacity  Range (kW)1.57~8.404.40~13.005.9~18.27.5~23.010.2~28.012.8~35.0
Heating input  Range (kW)0.32~1.870.90~3.021.20~4.111.53~5.232.07~6.362.61~7.99
current  Range  (A) 1.42~8.301.39~4.68/
4.12~13.8
1.86~6.37/
5.49~18.8
2.37~8.113.70~11.44.67~14.3
COP Range4.49~4.914.30~4.904.43~4.924.40~4.904.40~4.924.38~4.90
CoolingCooling capacity  Range (kW)0.99~6.222.80~8.203.81~11.534.73~14.66.54~19.88.13~24.6
Cooling Input power(kW)0.29~2.180.85~3.311.11~4.051.39~5.141.92~6.972.42~8.75
current  Range  (A) 1.28~9.671.32~5.13/
3.89~15.1
1.72~6.28/
5.08~18.5
2.16~7.973.43~12.54.33~15.6
EER Range2.85~3.412.48~3.292.85~3.432.84~3.402.84~3.402.81~3.36
DHWHeating capacity  Range (kW)1.28~6.813.52~10.504.80~14.726.1~18.512.3~20.413.6~22.6
Heating input  Range (kW)0.31~2.130.88~3.391.17~4.601.53~5.972.8~5.373.09~5.95
current  Range  (A) 1.38~9.451.36~5.26/
4.03~15.5
1.82~7.15/
5.35~21.1
2.37~9.265.0~9.65.52~10.6
COP Range3.2~4.13.1~4.03.2~4.13.1~4.03.8~4.43.8~4.4
Power Supply230V/1Ph/50-60Hz380V-400V/3Ph/50-60Hz /
220V-230V/1Ph/50-60Hz
380V/3Ph/50-60Hz
RefrigerantR32
 Working  Area -30~43℃
Water Circulation (m³/H)1.4 2.2 3.1 4.0 4.86.0 
Water Pressure Drop (kPa)312535454050
IP Grade (Level of protection)IPX4IPX4IPX4IPX4IPX4IPX4
Anti-electric Shock RateIIIIII
Noise (dB(A))≤53≤55≤57≤58≤62≤66
Net Weight/Gross Weight(kg)110/120140/150170/180180/190210/220230/240
Diameter of Pipe (mm)DN25DN25DN25DN25DN32DN32
Body Size(W*D*H) (mm)970×475×8351100×475×9851050×480×13301050×480×13301160×500×15801160×500×1580
Loading Quantity (20GP/40GP/40HQ)44/88/8844/88/8822/46/4622/46/4618/40/4018/40/40
ErP Level (35°C)A+++A+++A+++A+++A+++A+++
ErP Level (55°C)A++A++A++A++A++A++
Condensor TypePlate Heat Exchanger
Fan MotorDC Type
Defrosting By Four-way valve
Operating Water Temperature (℃) DHW9~60℃
Operating Water Temperature (℃) Heating9~50℃
Operating Water Temperature (℃) Cooling7~35℃
Remark:
Heating working condition: Inlet water temperature 30℃, Outlet water temperature 35℃, Dry bulb temperature 7℃, Wet bulb temperature6℃.
Cooling working condition:Inlet water temperature 12℃, Outlet water temperature 7℃, Dry bulb temperature 35℃, Wet bulb temperature 24℃.
DHW working condition: Inlet water temperature 15℃, Outlet water temperature 55℃, Dry bulb temperature 7℃, Wet bulb temperature 6℃.

    Contact Us